mini 3L Vaccine Transport Carrier Insulated Cold Chain Box For Deliver
| Model No.: | BD23288 |
| Color/Logo: | Any As Your Request |
| Payment: | ![]() |
| Shipping: | Ocean Shipping Service from China to Global |
| Lead Time: | Within 30 Days After Sample Confirmed & Deposit Received |
| Certificate: | CE,FDA,SGS,MSDS,ISO9001 |
- Product name::
- Vaccine Transport Cold Chain Box
- Item NO::
- BD8008
- Empty Capacity::
- 8L
- Playload Capacity::
- 3L
- Plastic handle or webbing shoulder strap::
- plastic handle or webbing shoulder strap for Choice
- Temperature data display::
- YES
- Weight: :
- 1.5kg
- Weight(including ice packs)::
- 4.1kg
- Cold source::
- 6pcs ice bricks
- Certificate::
- ISO,CE mark
Mini 8L Vaccine Transport Carrier Insulated Cold Chain Box For Delivery
Vaccine transport carrier are insulated containers that can be lined with cold source(ice bricks or ice packs) to keep vaccines and diluents cold during transportation and/or short period storage. It included aluminium foil liner which can hold frozen BD ice gel and avoid vaccine or medicine from touching ice gel.
Vaccine cold chain box is high performance, fully sealed, insulated vaccine carrier. Cooling is supplied by sealed pre- frozen BDIceGel units (MSDS attached). Provision is made for external temperature monitoring if required.
Vaccine transport carrier is designed by the manufacturer specifically to be used principally as a stand alone temporary containment or storage function where safe temperature limits areessential in transit, or during use, for medical products including vaccines for human beings in the prevention, treatment or alleviation of disease.
The cold box stays cool for 24-32 hours at 2 to 8° C at 35°C ambient temperature and for up to 40 hours below 25° C ambient temperature.
Technical Information
| Usable cold space dimension(cm): | 21.4*8.5*16.2cm | External/Internal Moulding(Injection Mouldings): | *PP EPC30R-H |
| Usable cold sapce Capacity(L): | 2.95Liters | Lid moulding(Interna & External Injection mouldings) | *PP EPC30R-H |
| Weight fully loaded(kg): | 4.1kg | Insulation Material: | Polyurethanes |
| Weight empty(kg) | 1.5kg | Liner Material: | PVC/Aluminium Foil Laminated,NBR thermal insulation |
| Exteranl dimension(L*W*H cm) | 34*21*24cm | Type of ice bricks required: | water packs |
| Internal dimension(L*W*H cm) | 28.7*15.9*16.2 cm | Bricks dimension: | 6pcs BDBH360 16*9.5*3cm |
| Cold life at +43°C ambient temp. | 24 hours | Ice bricks supplied | YES |
| Warm life at -10°C ambient temp. | 20 hours | Lid type and fixing | fixed hinges |
| temperature data display | YES, with one AG battery | Handle | webbing shoulder strap or hard Plastic handle for choice |
Application
Our vaccine carrier and cold boxes, specially designed to hold temperatures within essential safe temperature limits without electricity during transport or use for:
Vaccines,Insulin,Biopharmaceutical, Life Science and other Medical Products, IVD products and biological specimens,Selected fresh food, drink and dairy products.
Instruction
1.Set the refrigerator at -18°C or lower.
2. Check that all BD water ice bricks are filled to the mark. in a liquid state and do not leak. Reject any leaky packs.
3. For best results, place the BD water ice bricks in a single layer flat on trays in the refrigerator, sufficiently spaced for air flow over the surface of the bricks.
4.Freeze the BD water ice bricks for 24 hrs. minimum. The bricks must be competely solid before use.
5. Open the lid of cold boxes and put liner in place.
6. If a digital thermometer and/or high temperature alarm is installed, check the batteries, and replace if neccessary. Clean and check the cable and sensor.
7. Remove the BD Water Ice Bricks from the refrigertator. Condition by placing them flat in a well ventilated position at room temperature until the surface temperature rises to above 0°C (dew will form on the surface of the Bricks at this point).
8. Place the BD Water Ice Bricks in the liner pockets.
9 .Close the lid, and wait for the temperature inside the box to reduce to below 8°C.
10. Open the lid and transfer the Vaccine or other product directly from the refrigerator to vaccine carrier.
11. Place the thermometer sensor at the centroid of the cold space.
12. Close the lid of box and fasten button.
Note:
Depending on external factors such as the ambient temperature, ambient humidity, how many times the box is opened etc. As such the responsibility for ensuring the medication is kept cold enough is solely that of the user and Badu Technology Co., Ltd cannot be held responsible or liable.
BADU(XIAMEN) TECHNOLOGY CO., LTD. (the Manufacturer) warrants to the Original Purchaser that Tvaccine carriers and cold boxes manufactured and packaged by the company and delivered in new condition are fit for the purpose for which the products were designed and manufactured, and are warranted against defects in materials and workmanship which under normal use result in breakdown or other failure within a period of ONE YEAR (The Warranty Period) from date of original purchase.