Contact Us
Cold Chain Logistics solution Supplier, Keep your biologics at Safe Temperature.
Phone:+86-18250813896

mini 3L Vaccine Transport Carrier Insulated Cold Chain Box For Deliver

/Pieces|100 Pieces(Min.Order)
Model No.:BD23288
Color/Logo:Any As Your Request
Payment:
Shipping:Ocean Shipping Service from China to Global
Lead Time:Within 30 Days After Sample Confirmed & Deposit Received
Certificate:CE,FDA,SGS,MSDS,ISO9001
This product has a minimum quantity of 100 and we provide processing mode of OEM and ODM.
PRODUCT DETAILS
Product name::
Vaccine Transport Cold Chain Box
Item NO::
BD8008
Empty Capacity::
8L
Playload Capacity::
3L
Plastic handle or webbing shoulder strap::
plastic handle or webbing shoulder strap for Choice
Temperature data display::
YES
Weight: :
1.5kg
Weight(including ice packs)::
4.1kg
Cold source::
6pcs ice bricks
Certificate::
ISO,CE mark

Mini 8L Vaccine Transport Carrier Insulated Cold Chain Box For Delivery

Vaccine transport carrier are insulated containers that can be lined with cold source(ice bricks or ice packs) to keep vaccines and diluents cold during transportation and/or short period storage. It included aluminium foil liner which can hold frozen BD ice gel and avoid vaccine or medicine from touching ice gel.

Vaccine cold chain box is high performance, fully sealed, insulated vaccine carrier. Cooling is supplied by sealed pre- frozen BDIceGel units (MSDS attached). Provision is made for external temperature monitoring if required.

Vaccine transport carrier is designed by the manufacturer specifically to be used principally as a stand alone temporary containment or storage function where safe temperature limits areessential in transit, or during use, for medical products including vaccines for human beings in the prevention, treatment or alleviation of disease.

The cold box stays cool for 24-32 hours at 2 to 8° C at 35°C ambient temperature and for up to 40 hours below 25° C ambient temperature.

Technical Information

Usable cold space dimension(cm): 21.4*8.5*16.2cm External/Internal Moulding(Injection Mouldings): *PP EPC30R-H              
Usable cold sapce Capacity(L): 2.95Liters Lid moulding(Interna & External  Injection mouldings) *PP EPC30R-H
Weight fully loaded(kg): 4.1kg Insulation Material: Polyurethanes
Weight empty(kg) 1.5kg Liner Material: PVC/Aluminium Foil Laminated,NBR thermal insulation
Exteranl dimension(L*W*H cm) 34*21*24cm Type of ice bricks required:  water packs
Internal dimension(L*W*H cm) 28.7*15.9*16.2 cm Bricks dimension: 6pcs BDBH360 16*9.5*3cm
Cold life at +43°C ambient temp. 24 hours Ice bricks supplied YES
Warm life at -10°C ambient temp. 20 hours Lid type and fixing fixed hinges
temperature data display YES, with one AG battery Handle webbing shoulder strap or hard Plastic handle for choice

Application
Our vaccine carrier and cold boxes, specially designed to hold temperatures within essential safe temperature limits without electricity during transport or use for:
Vaccines,Insulin,Biopharmaceutical, Life Science and other Medical Products, IVD products and biological specimens,Selected fresh food, drink and dairy products. 


Instruction
1.Set the refrigerator at -18°C or lower.  
2.  Check that all BD water ice bricks are filled to the mark. in a liquid state and do not leak. Reject any leaky packs.
3. For best results, place the BD water ice bricks in a single layer flat on trays in the refrigerator, sufficiently spaced for air flow over the surface of the bricks.
4.Freeze the BD water ice bricks for 24 hrs. minimum. The bricks must be competely solid before use.
5. Open the lid of cold boxes and put liner in place.
6. If a digital thermometer and/or high temperature alarm is installed, check the batteries, and replace if neccessary. Clean and check the cable and sensor.
7. Remove the BD Water Ice Bricks from the refrigertator. Condition by placing them flat in a well ventilated position at room temperature until the surface temperature rises to above 0°C (dew will form on the surface of the Bricks at this point). 
8. Place the BD Water Ice Bricks in the liner pockets. 
9 .Close the lid, and wait for the temperature inside the box to reduce to below 8°C. 
10. Open the lid and transfer the Vaccine or other product directly from the refrigerator to vaccine carrier.
11. Place the thermometer sensor at the centroid of the cold space.
12. Close the lid of box and fasten button.

Note:
Depending on external factors such as the ambient temperature, ambient humidity, how many times the box is opened etc. As such the responsibility for ensuring the medication is kept cold enough is solely that of the user and Badu Technology Co., Ltd cannot be held responsible or liable.


PRODUCT WARRANTY
BADU(XIAMEN) TECHNOLOGY CO., LTD. (the Manufacturer) warrants to the Original Purchaser that Tvaccine carriers and cold boxes manufactured and packaged by the company and delivered in new condition are fit for the purpose for which the products were designed and manufactured, and are warranted against defects in materials and workmanship which under normal use result in breakdown or other failure within a period of ONE YEAR (The Warranty Period) from date of original purchase.



AGREEMENT POLICY

Payment

Shippment

Refund Policy

GET IN TOUCH

Room 1901, Building No. 69, Dongdu Road, Xiamen Area of China (Fujian) Pilot Free Trade Zone,361013

Phone:+86-18250813896

E-mail: badu@medicalcoolers.cn

NEWSLETTER
Badu (Xiamen) Technology Co.Ltd, Copyright © 2018-2019 medicalcoldbox.com , Inc. All rights reserved.
Show msg!

TOP